Filter Results By:

Products

Applications

Manufacturers

Showing results: 106 - 120 of 126 items found.

  • PXI-2565, 16-Channel, 7 A, SPST PXI Relay Module

    777754-01 - NI

    16-Channel, 7 A, SPST PXI Relay Module—The PXI‑2565 is a general-purpose switch module that features independent single‑pole single‑throw (SPST) Form A armature relays. It delivers high-current switching of DC power supplies, AC line power, and AC/DC current sources. The PXI‑2565 is fully software programmable and supports multiple instrument synchronization.

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • Solenoid-Saver

    B-1022-B - ROSS ENGINEERING CORPORATION

    *Solenoid-Saver® eliminates AC hum and reduces heat generation for many types of solenoids.*Controlled application of current prevents coil burnout if high pull-in/low holding current AC or DC solenoids fail to pull-in completely.*Can adapt high pull-in low holding current solenoids to special voltages & frequencies 12V to 250V DC or 12V to 240V AC wideband 25-800Hz.*Optional optical isolated control input 4 to 10V, 5MA, 20 usec or more (or other control voltages) to actuate any high current solenoid directly by computer or other low power signal source.*For coils of 1 ohm to 3,500 ohms DC resistance requiring up to 70 amps during pull-in up to 120 milliseconds. Basic solenoid coil voltage and resistance must be specified.*Eliminates heat producing dropping resistors, bypass switch, dual coils, laminations, & shading coils.*Can increase pull-in and holding force of many types of solenoids.*Optional stored energy to delay solenoid release on loss of power.*Can be used as an added accessory to existing solenoid installation to eliminate AC hum, lower coil temperature and prevent coil burnout.*Optional high speed, 1 microsecond sensing, 1-10 millisecond actuation with stored energy Solenoid-Saver®

  • Current and Voltage Calibrator/Meter

    Extech 412355A - Extech Instruments Corporation

    412355A is a Current and Voltage Calibrator and Meter. Precision source for calibrating process devices and measuring DC process signals from 0 to 24mA or as mV in voltage ranges with a super large LCD that displays readings in mA, as a percent of the 0 to 24mA range or as mV in voltage ranges. Additional features include Touch Keypad and five stored calibration values for fast calibrations. Complete with 9V Battery, calibration cable with spade lug terminals, carrying case, neck strap, and AC Power Adapter.

  • Dual Mobile Comm DC Source w/ Battery Emulation, DVM

    66319D - Keysight Technologies

    The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.

  • Dual Mobile Communications DC Source

    66309B - Keysight Technologies

    The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.

  • PXI-2567 , 64-Channel PXI Relay Driver Module

    778572-67 - NI

    64-Channel PXI Relay Driver Module—The PXI‑2567 is an external relay driver that works with internal or external power sources. The PXI‑2567 allows you to control relays when the current and voltage requirements for those relays exceed the capabilities found in existing relay modules or for relays embedded in a test system. The PXI‑2567 includes overcurrent, overvoltage, and flyback protection to ensure long-life operation. The PXI‑2567 can also drive small DC motors or other inductive relay coils.

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2220 - TREK, INC.

    Trek’s Model 2220 is one of several models within our 2200-series of high-voltage 40 W amplifiers. Provided at an attractive price and offering high performance, the unit incorporates DC stability, wide bandwidth and well regulated/controlled AC output signals. It also features full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and autorecovery shutdown to protect the output from being overpowered. The instrument stage sinks or sources current into reactive or resistive loads throughout the output voltage range making it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2210 - TREK, INC.

    Trek’s Model 2210 is one of several models within our 2200-series of high-voltage 40 W amplifiers. Provided at an attractive price and offering high performance, the unit incorporates DC stability, wide bandwidth and well regulated/controlled AC output signals. It also features full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and auto recovery shutdown to protect the output from being overpowered. The instrument stage sinks or sources current into reactive or resistive loads throughout the output voltage range making it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

  • Electronic DC Load, 500V, 16A, 400W

    LDH400 Series - Aim-TTi

    Versatile solution for direct testing of dc power sources and PFCsConstant current, resistance, conductance and power modesWide voltage and current range, 10 to 500V and 0 to 16A400 watts continuous dissipation at 28°C (360W at 40°C)High resolution and accuracy for level settingBuilt-in transient generator with variable slewCurrent monitor output for waveform viewingVariable drop-out voltage for battery testingHigh resolution backlit graphic LCD with soft key controlAnalogue remote control of levels and TTL control of on/off and transient switchingFront and rear input terminalsLoad inputs rated to CAT II (300V)Full bus control via USB, RS232 and LXI compliant LAN interfacesGPIB Option

  • Load Cell Power Supply

    MODEL PSMR - Transducer Techniques, Inc

    The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.

  • RCD/LOOP/PAT Testers

    Kyoritsu Electrical Instruments Works, Ltd.

    Custom microprocessor controlled for highest accuracy and reliability. 3 LEDs for checking correct wiring status. 0 and 180 degree phase angle switch permits quick tests and consistent readings. Digital read-out of tripping time. Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings. Large custom digital display readout. Visual indication of reversed phase and neutral wiring at socket. Designed to IP54 Rating. Complies with IEC 61557 Test of a large kind of RCD''''s: Standard, Selective, AC and A (DC sensitive breakers)

  • High-Density Precision SMU (10 PA, 30 V)

    PZ2131A - Keysight Technologies

    The Keysight PZ2131A is a high-channel density precision source / measure unit (SMU) having 5 channels per module and saving space for a wide range of applications requiring numerous precision power supplies. The narrow-pulse function and fast Digitizer Mode allow the PZ2131A to expand the conventional static DC measurements to emerging dynamic measurements. Its seamless current measurement ranging function eliminates the time it takes to change the range and expands the dynamic range to cover multiple measurement ranges, which reduces test duration. These capabilities make the PZ2131A suitable for applications that require numerous precision power supplies, such as semiconductor reliability tests and integrated circuit (IC) tests. The Keysight PX0107A low noise filter adapter lowers its voltage source noise level, which makes the PZ2131A suitable for noise-sensitive applications such as quantum computing as well.

  • Programmable High Power DC Power Supply

    ADG series - Preen AC Power Corp.

    Preen’s ADG series is a programmable DC power supply with high power density and high output power, and offers many great advantages on response time, accuracy and output voltage range. ADG is an excellent source for testing or facility type applications, such as aerospace, renewable energy, automated test system, battery and server. With power level up to 80kW per unit, the ADG series provides output voltage up to 1000V and high output current of 2000A after custom modification.

  • Electrical Safety Test Equipment

    IBEKO Power AB

    Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault to earth, test instruments generate a high current. The standard requires that the resistance between protective earth and any conductive surface on the equipment does not exceed 0,1 Ohm. The test is performed by applying a DC current between the conductive surface and protective earth. By measuring the voltage drop, it calculates the resistance.RMO-E instruments are ideal for testing the protective bonding (grounding) of equipment following the standard IEC 61010-1. Applying current up to the value of 100 A and the ability to provide in the Contin menu (continuous operation) test current for the pre-set test duration (equal or exceeding 1 min) gives a user a possibility to easily check the protective bonding/grounding of the equipment. The full load voltage of 12 V assures proper measurement and accurate result. Finally, an instrument displays pass/fail classification according to user-preset parameters.

Get Help